e-Health Sensor Platform V2.0 for Arduino and Raspberry Pi [Biometric / Medical Applications]

e-Health Sensor Platform V2.0 for Arduino and Raspberry Pi [Biometric / Medical Applications]

IMPORTANT: The new generation of the eHealth Sensor Platform is called MySignals. You can find below a brief description and a comparative between the old eHealth v2 Platform and MySignals. If you want to go to the eHealth Tutorial just click here.

Differences between the old eHealth Platform and MySignals
MySignals is the new generation of eHealth and medical development products specifically oriented to researchers, developers and makers. It has new features that significantly improve the previous version commonly known as eHealth v2.
  • The number of sensors has been increased from 10 to 16.
  • The new sensors availables are: Snore, Spirometer, Blood Pressure (BLE), SPO2 (BLE), Glucometer (BLE) and Body Scale (weight, bone mass, body fat, muscle mass, body water, visceral fat, Basal Metabolic Rate and Body Mass Index).
  • The accuracy of the sensors has been improved. Now we provide better and more reliable sensors.
  • The sensor probes are more robust now.
  • The new generation integrates a better MCU with 4 times more memory.
  • WiFi and BLE radios now integrated on the PCB.
  • A complete graphic system with a TFT touchscreen allows to see the data coming realtime from the sensors.
  • New 'audio type' jack connectors allows it to be used by non technical staff.
  • CE / FCC / IC certifications passed for MySignals SW.
  • Cloud Storage of the data is now available to save historical information.
  • Native Android / iOS App's can be used now to visualize the information in realtime and to browse the Cloud data.



Discover MySignals now!


In the next tables you can see a complete comparative between eHealth v2 and the two different models of MySignals.

GENERAL FEATURES
e-Health V2.0
MySignals SW
MySignals HW
Architecture
Arduino compatible
Libelium IoT Core
Arduino compatible
RAM Memory
2K
8K
2K
Microprocessor
Atmega 328 (Arduino UNO)
Atmega 2560
Atmega 328 (Arduino UNO)
Flash Memory
32K
256K
32K
UART sockets
1
1
1 (multiplexed)
Enclosure
Complete Kitl
SDK
Screen
GLCD - optional (basic graphics)
TFT (complete graphic interface)
TFT (basic graphics)
TouchScreen
Cloud Storage
Android / iOS App
API Cloud
API Android/iOS
Sensors
10
16
16
Wired Sensors
10
11
11
Wireless Sensors
10
16
16
Concurrent Sensor Readings
From any sensor (10) to one interface
From any sensor (16) to one interface (TFT, BLE, WiFi)
From one group of sensors (analog, UART, BLE) to one interface (TFT, BLE, WiFi)
Radios on board
-
BLE, WiFi
BLE, WiFi
Extra Radios
BT, ZigBee, 4G / 3G / GPRS
-
BT, ZigBee, 4G / 3G / GPRS
Certifications
-
CE / FCC / IC
-
 
SENSORS
eHealth V2.0
MySignals SW
MySignals HW
Body Position
Body temperature
Electromyography
Electrocardiography
Airflow
Galvanic Skin Response
Blood Pressure
Pulsioximeter
Glucometer
Spirometer
Snore
Scale (BLE)
Blood Pressure (BLE)
Pulsioximeter (BLE)
Glucometer (BLE)
Electroencephalography
IMPORTANT: The e-Health shield v2 and all its sensors will be available until stock lasts. Then the product will be discontinued and we will keep the tutorial and product pages for your reference only. We encourage you to start developing your new eHealth, medical and biometric projetcs with MySignals.

e-Health Sensor Platform V2.0 for Arduino and Raspberry Pi [Biometric / Medical Applications]



In August 2013 Cooking Hacks launched the new version of the first biometric shield for Arduino and Raspberry Pi: the e-Health Sensor Platform V2.0. Thanks to the feedback given by the Community and several projects that have been created with it, we have improved the e-Health platform with new features such as:
  • New muscle sensor
  • New blood pressure sensor
  • Upgraded glucometer
  • New Connection possibilities
In this tutorial we will explain how to work with e-Health Sensor Platform V2.0. If you have e-Health V1 you can see how to use it on this link:
The e-Health Sensor Shield V2.0 allows Arduino and Raspberry Pi users to perform biometric and medical applications where body monitoring is needed by using 10 different sensors: pulse, oxygen in blood (SPO2), airflow (breathing), body temperature, electrocardiogram (ECG), glucometer, galvanic skin response (GSR - sweating), blood pressure (sphygmomanometer), patient position (accelerometer) and muscle/eletromyography sensor (EMG).
This information can be used to monitor in real time the state of a patient or to get sensitive data in order to be subsequently analysed for medical diagnosis. Biometric information gathered can be wirelessly sent using any of the 6 connectivity options available: Wi-Fi, 3G, GPRS, Bluetooth, 802.15.4 and ZigBee depending on the application.
If real time image diagnosis is needed a camera can be attached to the 3G module in order to send photos and videos of the patient to a medical diagnosis center.
Data can be sent to the Cloud in order to perform permanent storage or visualized in real time by sending the data directly to a laptop or Smartphone. iPhone and Android applications have been designed in order to easily see the patient's information.
Quick FAQ
  • What does it mean to count with an open medical monitoring platform?
  • Cooking Hacks wants to give Community the necessary tools in order to develop new e-Health applications and products. We want Arduino and Raspberry Pi Community to use this platform as a quick proof of concept and the basis of a new era of open source medical products.
  • How do I ensure the privacy of the biometric data sent?
  • Privacy is one of the key points in this kind of applications. For this reason the platform includes several security levels:
    • In the communication link layer: AES 128 for 802.14.5 / ZigBee and WPA2 for Wifi.
    • In the application layer: by using the HTTPS (secure) protocol we ensure a point to point security tunnel between each sensor node and the web server (this is the same method as used in the bank transfers).
e-Health Sensor Shield over Arduino (left) Raspberry Pi (right)
IMPORTANT: The e-Health Sensor Platform has been designed by Cooking Hacks (the open hardware division of Libelium) in order to help researchers, developers and artists to measure biometric sensor data for experimentation, fun and test purposes. Cooking Hacks provides a cheap and open alternative compared with the proprietary and price prohibitive medical market solutions. However, as the platform does not have medical certifications it can not be used to monitor critical patients who need accurate medical monitoring or those whose conditions must be accurately measured for an ulterior professional diagnosis.

1. FeaturesGo to index 

The pack we are going to use in this tutorial is the eHealth Sensor platform from Cooking Hacks. The e-Health Sensor Shield is fully compatible with Raspberry and new and old Arduino USB versions, Duemilanove and Mega.
  • 8 non-invasive + 1 invasive medical sensors
  • Storage and use of glucose measurements.
  • Monitoring ECG signal.
  • Monitoring EMG signals.
  • Airflow control of patient.
  • Airflow control of patient.
  • Body temperature data.
  • Galvanic skin response measurements.
  • Body position detection.
  • Pulse and oxygen functions.
  • Blood pressure control device.
  • Multiple data visualization systems.
  • Compatible with all UART device.

Electrical features:

The e-Health shield can be powered by the PC or by an external power supply. Some of the USB ports on computers are not able to give all the current the module needs to work, if your module have problems when it work, you can use an external power supply (12V - 2A) on the Arduino/RasberryPi.

2. The shieldGo to index 

e-Health PCB

Schematics

e-Health shield over Arduino

 
The shields:

e-Health shield over Raspberry Pi

In order to connect the e-Health Sensor Shield to Raspberry Pi an adaptor shield is needed.Click here to know more about the Raspberry Pi to Arduino Shields Connection board.
The shields:
Warnings:
  • The LCD, the sphygmomanometer and communication modules use the UART port and can't work simultaneously.
  • The glucometer is now compatible with other UART devices and it has its own connector. But it can not work with the sphygmomanometer connected.
  • The EMG sensor and the ECG can't work simultaneously. Use the jumpers integrated in the board to use one or the other
  • To use the EMG sensor, you'll need to have the jumpers in the EMG position. To use the ECG sensor, you'll need to have the jumpers in the ECG configuration.

3. The libraryGo to index 

Note: these examples are written for Arduino 1.0.1. Certain functions may not work in other versions.
The e-health Sensor Platform counts with a C++ library that lets you read easily all the sensors and send the information by using any of the available radio interfaces. This library offers an simple-to-use open source system.
In order to ensure the same code is compatible in both platforms (Arduino and Raspberry Pi) we use the ArduPi libraries which allows developers to use the same code. Detailed info can be found here:

Using the library with Arduino

The eHealth sensor platform includes a high level library functions for a easy manage of the board. This zip includes all the files needed in two separated folders, “eHealth” and “PinChangeInt”. The “PinChangeInt” library is necessary only when you use the pulsioximeter sensor. Copy this folders in the arduino IDE folder “libraries”. Don't forget include these libraries in your codes.
You must download the library depending on the date of purchase.
Libraries are often distributed as a ZIP file or folder. The name of the folder is the name of the library. Inside the folder will be the .cpp files, .h files and often a keywords.txt file, examples folder, and other files required by the library.
To install the library, first quit the Arduino application. Then uncompress the ZIP file containing the library. For installing eHealth library , uncompress eHealth.zip. It should contain a folder called “eHealth” and another called “PinChangeInt”, with files like eHealth.cpp and eHealth.h inside. Drag the eHealth and PinChange folders into this folder (your libraries folder). Under Windows, it will likely be called "My Documents\\Arduino\\libraries". For Mac users, it will likely be called "Documents/Arduino/libraries". On Linux, it will be the "libraries" folder in your sketchbook.
The library won't work if you put the .cpp and .h files directly into the libraries folder or if they're nested in an extra folder. Restart the Arduino application. Make sure the new library appears in the Sketch->Import Library menu item of the software.
That's it! You've installed a library!

Using the library with Raspberry Pi

The e-Health library for Raspberry Pi requires the ArduPi library and both libraries should be in the same path.
You must download the library depending on the date of purchase.
Creating a program that uses the library is as simple as putting your code in this template where it says "your arduino code here"
Code:
Compilation of the program can be done in two ways:
  • Compiling separately eHealth and arduPi, and using them for compiling the program in a second step:
    g++ -c arduPi.cpp -o arduPi.o
    
    g++ -c eHealth.cpp -o eHealth.o
    
    g++ -lpthread -lrt user-e-health-app.cpp arduPi.o eHealth.o -o user-e-health-app
                    
  • Compiling everithing in one step:
    g++ -lpthread -lrt user-e-health-app.cpp arduPi.cpp eHealth.cpp -o user-e-health-app
                    
Executing your program is as simple as doing:
sudo ./user-e-health-app
                

General e-Health functions

Pulsioximeter sensor functions:
initPulsioximeter()      // It initialize the pulsioximeter sensor.
readPulsioximeter()      // It reads a value from pulsioximeter sensor.
getBPM()                 // Returns the heart beats per minute.
getOxygenSaturation()    // Returns the oxygen saturation in blood in percent.
                
ECG sensor funcion:
getECG() // Returns an analogic value to represent the Electrocardiography.
                
EMG sensor funcion:
getEMG() // Returns an analogic value to represent the Electromyography.
                
AirFlow sensor funcions:
getAirFlow()  // Returns an analogic value to represent the air flow.
airFlowWave() // Prints air flow wave form in the serial monitor.
                
Temperature sensor function:
getTemperature() // Returns the corporal temperature.
                
Blood pressure functions:
initBloodPressureSensor() // It initialize and measure  the blood pressure sensor.
getBloodPressureSensor()  // Returns the number of data stored in the blood pressure sensor.
getSystolicPressure(i)    // Returns the  value of the systolic pressure number i.
getDiastolicPressure(i)   // Returns the  value of the diastolic pressure number i.
                
Body position sensor functions:
initPositionSensor() // It initialize  the position sensor.
getBodyPosition()    // Returns the body position.
printPosition()      // Prints the current body position.
                
GSR sensor functions:
getSkinConductance()        // Returns the value of skin conductance.
getSkinResistance()         // Returns the value of skin resistance.
getSkinConductanceVoltage() // Returns the value of skin conductance in voltage.
                
Glucometer sensor functions:
readGlucometer()      // Read the values stored in the glucometer.
GetGlucometerLength() // Returns the number of data stored in the glucometer.
numberToMonth()       // Convert month variable from numeric to character.
                

4. Sensor PlatformGo to index 

Pulse and Oxygen in Blood (SPO2)

SPO2 sensor features

Pulse oximetry a noninvasive method of indicating the arterial oxygen saturation of functional hemoglobin.
Oxygen saturation is defined as the measurement of the amount of oxygen dissolved in blood, based on the detection of Hemoglobin and Deoxyhemoglobin. Two different light wavelengths are used to measure the actual difference in the absorption spectra of HbO2 and Hb. The bloodstream is affected by the concentration of HbO2 and Hb, and their absorption coefficients are measured using two wavelengths 660 nm (red light spectra) and 940 nm (infrared light spectra). Deoxygenated and oxygenated hemoglobin absorb different wavelengths.
Deoxygenated hemoglobin (Hb) has a higher absorption at 660 nm and oxygenated hemoglobin (HbO2) has a higher absorption at 940 nm . Then a photo-detector perceives the non-absorbed light from the LEDs to calculate the arterial oxygen saturation.
pulse oximeter sensor is useful in any setting where a patient's oxygenation is unstable, including intensive care, operating, recovery, emergency and hospital ward settings, pilots in unpressurized aircraft, for assessment of any patient's oxygenation, and determining the effectiveness of or need for supplemental oxygen.
Acceptable normal ranges for patients are from 95 to 99 percent, those with a hypoxic drive problem would expect values to be between 88 to 94 percent, values of 100 percent can indicate carbon monoxide poisoning.
The sensor needs to be connected to the Arduino or Raspberry Pi, and don't use external/internal battery.
IMPORTANT: The Pulse and Oxygen in Blood Sensor (SPO2) is NOT compatible with the Raspberry Pi 3

Connecting the sensor

Connect the module in the e-Health sensor platform. The sensor have only one way of connection to prevent errors and make the connection easier.
Insert your finger into the sensor and press ON button.
After a few seconds you will get the values in the sensor screen.
IMPORTANT: The Pulse and Oxygen in Blood Sensor (SPO2) is NOT compatible with the Raspberry Pi 3

Library functions

Initializing
This sensor use interruptions and it is necessary to include a special library when you are going to use it.
#include < PinChangeInt.h >
                
After this include, you should attach the interruptions in your code to get data from th sensor. The sensor will interrupt the process to refresh the data stored in private variables.
PCintPort::attachInterrupt(6, readPulsioximeter, RISING);
                
The digital pin 6 of Arduino is the pin where sensor send the interruption and the function readpulsioximeter will be executed.
void readPulsioximeter(){
 cont ++;
 if (cont == 50) { //Get only one 50 measures to reduce the latency
  eHealth.readPulsioximeter();
  cont = 0;
 }
}
                
Before start using the SP02 sensor, it must be initialized. Use the next function in setup to configure some basic parameters and to start the communication between the Arduino/RaspberryPi and sensor.
Reading the sensor
For reading the current value of the sensor, use the next function.
Example:
{
 eHealth.readPulsioximeter();
}
                
This function will store the values of the sensor in private variables.
Getting data
To view data we can get the values of the sensor stored in private variable by using the next functions.
Example:
{
 int SPO2 = eHealth.getOxygenSaturation()
 int BPM = eHealth.getBPM()
}
                

Example

Arduino
Upload the next code for seeing data in the serial monitor:
Code:
Upload the code to Arduino and watch the Serial monitor.Here is the USB output using the Arduino IDE serial port terminal:
Raspberry Pi
Code:
NOTE:This sensor can not be used with Raspberry Pi to Arduino Shields Connection Bridge v2 plus a Communication module in the XBee socket. The same Digital Pin used by the SPO2 sensor (Digital 3) is used by the new version of the Bridge to enable/disable the communication module.
Mobile app
The App shows the information the nodes are sending which contains the sensor data gathered Smartphone app
GLCD
The GLCD shows the information the nodes are sending which contains the sensor data gathered. GLCD

Electrocardiogram (ECG)

ECG sensor features

The electrocardiogram (ECG or EKG) is a diagnostic tool that is routinely used to assess the electrical and muscular functions of the heart.
Electrocardiogram Sensor (ECG) has grown to be one of the most commonly used medical tests in modern medicine. Its utility in the diagnosis of a myriad of cardiac pathologies ranging from myocardial ischemia and infarction to syncope and palpitations has been invaluable to clinicians for decades.
The accuracy of the ECG depends on the condition being tested. A heart problem may not always show up on the ECG. Some heart conditions never produce any specific ECG changes. ECG leads are attached to the body while the patient lies flat on a bed or table.
What is measured or can be detected on the ECG (EKG)?
The orientation of the heart (how it is placed) in the chest cavity.
Evidence of increased thickness (hypertrophy) of the heart muscle.
Evidence of damage to the various parts of the heart muscle.
Evidence of acutely impaired blood flow to the heart muscle.
Patterns of abnormal electric activity that may predispose the patient to abnormal cardiac rhythm disturbances.
The underlying rate and rhythm mechanism of the heart.
Schematic representation of normal ECG

Connecting the sensor

Connect the three leads (positive, negative and neutral) in the e-Health board.
Connect the ECG lead to the electrodes.
Remove the protective plastic
Place the electrodes as shown below

ECG sensor features

Getting data
This ECG returns an analogic value in volts (0 – 5) to represent the ECG wave form.
Example:
{
 float ECGvolt = eHealth.getECG();
}
                

Example

Arduino
Upload the next code for seeing data in the serial monitor:
Code:
Upload the code and watch the Serial monitor. Here is the USB output using the Arduino IDE serial port terminal:
Raspberry Pi
Code:
Mobile App
The App shows the information the nodes are sending which contains the sensor data gathered. Smartphone app
GLCD
The GLCD shows the information the nodes are sending which contains the sensor data gathered. GLCD
KST
KST program shows the ECG wave. KST

Airflow: breathing

Airflow sensor features

Anormal respiratory rates and changes in respiratory rate are a broad indicator of major physiological instability, and in many cases, respiratory rate is one of the earliest indicators of this instability. Therefore, it is critical to monitor respiratory rate as an indicator of patient status. AirFlow sensor can provide an early warning of hypoxemia and apnea.
The nasal / mouth airflow sensor is a device used to measure the breathing rate in a patient in need of respiratory help or person. This device consists of a flexible thread which fits behind the ears, and a set of two prongs which are placed in the nostrils. Breathing is measured by these prongs.
The specifically designed cannula/holder allows the thermocouple sensor to be placed in the optimal position to accurately sense the oral/nasal thermal airflow changes as well as the nasal temperature air. Comfortable adjustable and easy to install.
Single channel oral or nasal reusable Airflow Sensor. Stay-put prongs position sensor precisely in airflow path.
A normal adult human has a respiratory rate of 15–30 breaths per minute.

Connecting the sensor

The e-Health AirFlow sensor have two connections (positive and negative)
Connect the red wire with the positive terminal (marked as “+” in the board) and the black wire with the negative terminal (marked as “-” in the board)
After connecting the cables, tighten the screws
Place the sensor as shown in the picture below

Library functions

Getting data
The air flow sensor is connected to the Arduino/RasberryPi by an analog input and returns a value from 0 to 1024. With the next functions you can get this value directly and print a wave form in the serial monitor.
Example:
{
 int airFlow = eHealth.getAirFlow();
 eHealth.airFlowWave(air);
}
                

Example

Arduino
Upload the next code for seeing data in the serial monitor:
Code:
Upload the code and watch the Serial monitor.Here is the USB output using the Arduino IDE serial port terminal:
Raspberry Pi
Compile this example code:
Code:
Mobile app
The App shows the information the nodes are sending which contains the sensor data gathered Smartphone app
GLCD
The GLCD shows the information the nodes are sending which contains the sensor data gathered. GLCD
KST
KST program shows the airflow wave. KST

Body temperature

Temperature sensor features

Body temperature depends upon the place in the body at which the measurement is made, and the time of day and level of activity of the person. Different parts of the body have different temperatures.
The commonly accepted average core body temperature (taken internally) is 37.0°C (98.6°F). In healthy adults, body temperature fluctuates about 0.5°C (0.9°F) throughout the day, with lower temperatures in the morning and higher temperatures in the late afternoon and evening, as the body's needs and activities change.
It is of great medical importance to measure body temperature. The reason is that a number of diseases are accompanied by characteristic changes in body temperature. Likewise, the course of certain diseases can be monitored by measuring body temperature, and the efficiency of a treatment initiated can be evaluated by the physician.
Hypothermia<35.0 °C (95.0 °F)
Normal36.5–37.5 °C (97.7–99.5 °F)
Fever or Hyperthermia>37.5–38.3 °C (99.5–100.9 °F
Hyperpyrexia>40.0–41.5 °C (104–106.7 °F)

Sensor Calibration

The precision of the Body Temperature Sensor is enough in most applications. But you can improve this precision by a calibration process.
When using temperature sensor, you are actually measuring a voltage, and relating that to what the operating temperature of the sensor must be. If you can avoid errors in the voltage measurements, and represent the relationship between voltage and temperature more accurately, you can get better temperature readings.
Calibration is a process of measuring voltage and resistance real values. In the eHealth.cpp file we can find getTemperature function. The values [Rc, Ra, Rb, RefTension] are imprecisely defined by default.
If you measure these values with a multimeter and modify the library will obtain greater accuracy.
Place multimeter ends at the extremes of the resistors and measure the resistance value. In this case we would modify resistance value (Ra=4640 / Rb=819)...
Make the same process between 3V (red cable) and GND (black cable) but with the multimeter in voltage measurement. In this case we would not change the value.

Connecting the sensor

For taking measures of temperature, connect the sensor in the jack connector.
Make contact between the metallic part and your skin
Use a piece of adhesive tape to hold the sensor attached to the skin

Library functions

Getting data
The corporal temperature can be taken by a simple function. This function return a float with the last value of temperature measured by the Arduino/RasberryPi.
Example:
{
 float temperature = eHealth.getTemperature();
}
                

Example

Arduino
Upload the next code for seeing data in the serial monitor:
Code:
Upload the code and watch the Serial monitor. Here is the USB output using the Arduino IDE serial port terminal:
Raspberry Pi
Compile the following example code:
Code:
Mobile App
The App shows the information the nodes are sending which contains the sensor data gathered Smartphone app
GLCD
The GLCD shows the information the nodes are sending which contains the sensor data gathered. GLCD

Blood pressure

Blood pressure sensor features

Blood pressure is the pressure of the blood in the arteries as it is pumped around the body by the heart. When your heart beats, it contracts and pushes blood through the arteries to the rest of your body. This force creates pressure on the arteries. Blood pressure is recorded as two numbers—the systolic pressure (as the heart beats) over the diastolic pressure (as the heart relaxes between beats).
Monitoring blood pressure at home is important for many people, especially if you have high blood pressure. Blood pressure does not stay the same all the time. It changes to meet your body’s needs. It is affected by various factors including body position, breathing or emotional state, exercise and sleep. It is best to measure blood pressure when you are relaxed and sitting or lying down.
Classification of blood pressure for adults (18 years and older)
Systolic (mm Hg)Diastolic (mm Hg)
Hypotension< 90< 60
Desired90–11960–79
Prehypertension120–13980–89
Stage 1 Hypertension140–15990–99
Stage 2 Hypertension160–179100–109
Hypertensive Crisis≥ 180≥ 110
High blood pressure (hypertension) can lead to serious problems like heart attack, stroke or kidney disease. High blood pressure usually does not have any symptoms, so you need to have your blood pressure checked regularly.
SPECIAL FEATURES:
  • Automatic measurement of systolic, diastolic and pulse with time & date
  • Large LCD screen with LED backlight
  • TOUCH PAD KEY
  • 80 measurement results with time & date stored in the device
KEY SPECIFICATIONS:
  • Measurement method:Oscillometric system
  • Display type:Digital LCD 97mm [L] x 87mm [W]
  • Measuring range: Pressure 0-300 mmHg
  • Pulse 30~200 p/min
  • Measuring accuracy: Pressure≤±3 mmHg
  • Pulse≤5%
  • Operating environment: Temperature 10-40℃
  • Relative humidity≤80%
  • Power source: 4 x AA batteries
  • Dimension: 150mm [L] x 110mm [W] x 65mm [H]
  • Weight: About 370g
  • Cuff size: 520mm [L] x 135mm [W]
  • Cuff range: 220mm [L] - 320mm [W]

Compatible with ehealth V1

The new Blood Pressure Sensor (Sphygmomanometer) is compatible with e-Health Sensor Shield version 1 using an adapter cable.
The connection of this sensor in other e-Health versions is very simple. You must use the GLCD connector and connect the device as shown in the next picture.
This sensor only runs with the updated e-Health library. So it is necessary to follow the same next steps.
NOTE: The LCD, the sphygmomanometer and communication modules use the UART port and can't work simultaneously.

Connecting the sensor

Before start using the sphygmomanometer we need one measure at least in the memory of the blood pressure sensor. After that we can get all the information contained in the device.
Place the sphygmomanometer on your arm (biceps zone) as shown in the image below. Power the device.
Turn on the sphygmomanometer cuff (press ON button). The sensor will begin to make a measurement. After a few seconds the result is shown in the sphygmomanometer screen.
The blood pressure sensor will take a few moments to calculate the blood sugar reading. It will store the values in the memory.
In order to extract the data from the sphygmomanometer to the Arduino or Raspberry Pi, connect the cable as show in the picture.
NOTE: If you are using this sensor in other e-Health versions you must use an adapter cable.
You should view in the sphygmomanometer screen the message “UUU”, which indicates the correct connection.
Connect the jack terminal to the e-Health board blood pressure connector and the mini-USB terminal to the sphygmomanometer.
The cable is composed of two adapter cables as shown in the following image.
In order to measure correctly, it is important to maintain the arm and the cuff in the correct position.
Do not make abrupt movements or the measure will be not reliable.

Library functions

NOTE: You can modify the library in order to read more data. With some sketches, the buffer of the UART may be small, to increase the length of the buffer you need to change these lines in the file HardwareSerial.cpp (/arduino-1.0.X/hardware/arduino/cores/arduino):
#if (RAMEND < 1000)
#define SERIAL_BUFFER_SIZE 32
#else
#define SERIAL_BUFFER_SIZE 256
#endif
                
by
#if (RAMEND < 1000)
#define SERIAL_BUFFER_SIZE 256
#else
#define SERIAL_BUFFER_SIZE 256
#endif
                
You can increase the serial buffer size from 64 to 256 or 512 bytes in the Arduino.app package to have more buffer to receive the data from the BP meter.
But the serial buffer in Arduino is limited. In order to obtain more measures you could work with RaspberryPi.
Another option would be to try to store the measurement data on a SD, without showing on screen.
Getting blood pressure data
Some parameters must be initialized to start using blood pressure sensor (sphygmomanometer). The next function initializes some variables and reads the sphygmomanometer data.
{
 eHealth.readBloodPressureSensor();
  Serial.begin(115200);
}
                
The amount of data read is accessible with a another public function.
Example of use:
{
 uint8_t numberOfData = eHealth.getBloodPressureLength();
 Serial.print(F("Number of measures : "));
 Serial.println(numberOfData, DEC);
 delay(100);
}
                
The next functions return the values of systolic and diastolic pressure measured by the sphygmomanometer and stored in private variables of the e-Health class.
Example of use:
{
 int systolic = eHealth.getSystolicPressure(1);
 int diastolic =eHealth.getDiastolicPressure(1);
}
                
The number that we give to the function in the variable i is the number of the measurement we want to obtain.

Example

Arduino
Upload the next code for seeing data in the serial monitor:
Code:
Upload the code and watch the Serial monitor.Here is the USB output using the Arduino IDE serial port terminal:
Raspberry Pi
Code:
Get the Blood Pressure Sensor (Sphygmomanometer) v2.0

Patient position and falls

The Patient Position Sensor (Accelerometer) monitors five different patient positions (standing/sitting, supine, prone, left and right.)
In many cases, it is necessary to monitor the body positions and movements made because of their relationships to particular diseases (i.e., sleep apnea and restless legs syndrome). Analyzing movements during sleep also helps in determining sleep quality and irregular sleeping patterns. The body position sensor could help also to detect fainting or falling of elderly people or persons with disabilities.
eHealth Body Position Sensor uses a triple axis accelerometer to obtain the patient's position.
Features:
  • 1.95 V to 3.6 V supply voltage
  • 1.6 V to 3.6 V interface voltage
  • ±2g/±4g/±8g dynamically selectable full-scale
This accelerometer is packed with embedded functions with flexible user programmable options, configurable to two interrupt pins.The accelerometer has user selectable full scales of ±2g/±4g/±8g with high pass filtered data as well as non filtered data available real-time.
Body position

Connecting the sensor

The body position sensor has only one and simple way of connection. Connect the ribbon cable with the body position sensor and the e-Health board as show in the image below.
Place the tape around the chest and the connector placed down

Library functions

The e-Health library allows a simple programing way. With one simple function we can get the position of the patient and show it in the serial monitor of the Arduino/RasberryPi or in the GLCD.
Initializing the sensor
Before start using the sensor, we have to initialize some parameters. Use the next function to configure the sensor.
Example
{
 eHealth.initPositionSensor();
}
            
Getting data
The next functions return the a value that represent the body position stored in private variables of the e-Health class.
Example
{
 uint8_t position = eHealth.getBodyPosition();
}
            
The position of the pacient
    1 == Supine position.
    2 == Left lateral decubitus.
    3 == Rigth lateral decubitus.
    4 == Prone position.
    5 == Stand or sit position.
Printing Data
For representing the data in a easy way in the Arduino/RasberryPi serial monitor, e-health library, includes a printing function.
Example:
{
 Serial.print("Current position : ");
 uint8_t position = eHealth.getBodyPosition();
 eHealth.printPosition(position);
}
            

Example

Arduino
Upload the next code for seeing data in the serial monitor:
Code:
Upload the code and watch the Serial monitor.Here is the USB output using the Arduino IDE serial port terminal:
Raspberry Pi
Code:
Mobile App
The App shows the information the nodes are sending which contains the sensor data gathered Smartphone app
GLCD
The GLCD shows the information the nodes are sending which contains the sensor data gathered. GLCD

Galvanic Skin Response (GSR)

GSR sensor features

Skin conductance, also known as galvanic skin response (GSR) is a method of measuring the electrical conductance of the skin, which varies with its moisture level. This is of interest because the sweat glands are controlled by the sympathetic nervous system, so moments of strong emotion, change the electrical resistance of the skin. Skin conductance is used as an indication of psychological or physiological arousal, The Galvanic Skin Response Sensor (GSR - Sweating) measures the electrical conductance between 2 points, and is essentially a type of ohmmeter.
In skin conductance response method, conductivity of skin is measured at fingers of the palm. The principle or theory behind functioning of galvanic response sensor is to measure electrical skin resistance based on sweat produced by the body. When high level of sweating takes place, the electrical skin resistance drops down. A dryer skin records much higher resistance. The skin conductance response sensor measures the psycho galvanic reflex of the body. Emotions such as excitement, stress, shock, etc. can result in the fluctuation of skin conductivity. Skin conductance measurement is one component of polygraph devices and is used in scientific research of emotional or physiological arousal.

Sensor Calibration

The precision of the sensor is enough in most applications. But you can improve this precision by a calibration process.
When using temperature sensor, you are actually measuring a voltage, and relating that to what the operating temperature of the sensor must be. If you can avoid errors in the voltage measurements, and represent the relationship between voltage and temperature more accurately, you can get better temperature readings.
Calibration is a process of measuring real voltage values. In the eHealth.cpp file we can find getSkinConductance and getSkinResistance functions. The value 0.5 is imprecisely defined by default.
If you measure this voltage value with a multimeter and modify the library will obtain greater accuracy.
Place multimeter ends between 0.5V (Red cable) and GND (Black cable). In this case we would modify 0.5 to 0.498.

Connecting the sensor

Connect the to wires in the GSR contacts. The contacts have not polarization.
The galvanic skin sensor has two contacts and it works like a ohmmeter measuring the resistance of the materials. Place your fingers in the metallic contacts and tighten the velcro as shown in the image below.

Library functions

Getting data
With this simple functions we can read the value of the sensor. The library returns the value of the skin resistance and the skin conductance.
Example:
{
 float conductance = eHealth.getSkinConductance();
 float resistance = eHealth.getSkinResistance();
  float conductanceVol = eHealth.getSkinConductanceVoltage();
}
    

Example

Arduino
Upload the next code for seeing data in the serial monitor:
Code:
The App shows the information the nodes are sending which contains the sensor data gathered Smartphone app
GLCD
The GLCD shows the information the nodes are sending which contains the sensor data gathered. GLCD
KST
KST program shows the GSR wave. KST

Glucometer

Glucometer sensor features

Glucometer is a medical device for determining the approximate concentration of glucose in the blood. A small drop of blood, obtained by pricking the skin with a lancet, is placed on a disposable test strip that the meter reads and uses to calculate the blood glucose level. The meter then displays the level in mg/dl or mmol/l.
Despite widely variable intervals between meals or the occasional consumption of meals with a substantial carbohydrate load, human blood glucose levels tend to remain within the normal range. However, shortly after eating, the blood glucose level may rise, in non-diabetics, temporarily up to 7.8 mmol/L (140 mg/dL) or a bit more.
Glucometer configuration
For configuring the date time, open the batery compartment and press the black button. It's simple to set the parameters of our glucometer.
Did you see a small button near the battery (backside)? You can set the time and mg/dl by it. When glucometer is off, plz press once short time of the backside button to open it, then you can see the screen of year month date and time, short press the front button is to increase the data (long pressing will increase the data fast), short pree the backside botton is to switch the year to month/date or time or glucose units. To save the settings, plz short press the backside button several times until you see the big OFF on screen, then plz do nothing just wait it auto off.
To change the glucose units, when you see the time screen, just keeping short presses for several times untill you see only mmol/l is flashing, then press the front big button in long time (about 3 secs), you will see the mmol/l becomes to mg/dl. Now plz press the back small button twice short times to save it. You can see big OFF on screen, then plz do nothing just wait it auto off. Now you finished the settings of mg/dl. Setting other parameters is similar.

Connecting the sensor

Before start using the glucometer we need one measure at least in the memory of the glucometer. After that we can get all the information contained in the glucometer( date, glucose value).
Turn on the glucometer and place a test strip in the machine when the machine is ready. Watch the indicator for placing the blood to the strip.
Clean the end of your index finger with rubbing alcohol before pricking it with an sterile needle or lancet.
NOTE:The needles or lancets are not provided.
Pierce your finger tip on the soft, fleshy pad and obtain a drop of blood. The type of drop of blood is determined by the type of strip you are using
Place the drop of blood on or at the side of the strip.
The glucometer will take a few moments to calculate the blood sugar reading.
The glucometer will store the value in the memory.
In order to extract the data from the glucometer to the Arduino or Raspberry Pi, connect the cable as show in the picture.
You should view in the glucometer screen the message “P-C”, that indicates the correct connection.

Library functions

Getting data
With a simple function we can read all the measures stored in the glucometer and show them in the terminal. The function must be used before the intilizazion of the serial monitor.
Example of use:
{
 eHealth.readGlucometer();
 Serial.begin(115200);
}
            
The amount of data read is accessible with a another public function.
Example of use:
{
 uint8_t numberOfData eHealthClass.getGlucometerLength()
}
            
The maximum number of measures is 32. The vector where data is a public variable of the e-Health class.
Example of use:
{
    Serial.print(F("Glucose value : "));
    Serial.print(eHealth.glucoseDataVector[i].glucose);
    Serial.println(F(" mg/dL"));
}
            

Example

Arduino
Upload the next code for seeing data in the serial monitor:
Code:
Upload the code and watch the Serial monitor.Here is the USB output using the Arduino IDE serial port terminal:
Raspberry Pi
Compile the following code:
Code:
Get the Glucometer Sensor

Electromyogram (EMG)

EMG sensor features

An electromyogram (EMG) measures the electrical activity of muscles at rest and during contraction.
Electromyography (EMG) is a technique for evaluating and recording the electrical activity produced by skeletal muscles. EMG is performed using an instrument called an electromyograph, to produce a record called an electromyogram. An electromyograph detects the electrical potential generated by muscle cells when these cells are electrically or neurologically activated. The signals can be analyzed to detect medical abnormalities, activation level, recruitment order or to analyze the biomechanics of human or animal movement.
EMG signals are used in many clinical and biomedical applications. EMG is used as a diagnostics tool for identifying neuromuscular diseases, assessing low-back pain, kinesiology, and disorders of motor control. EMG signals are also used as a control signal for prosthetic devices such as prosthetic hands, arms, and lower limbs.
This sensor will measure the filtered and rectified electrical activity of a muscle, depending the amount of activity in the selected muscle.
Features:
  • Adjustable gain
  • Small Form Factor
  • Full integrated
Use your muscles to control any type of actuator (motors, servos, lights ...). Interact with the environment with your own muscles.
This sensor comes with everything you need to start sensing muscle activity with your Arduino or Raspberry Pi.
NOTE: The current EMG sensor has been designed by Advancer Technologies under a CC BY-NC-SA 3.0 license

Connecting the sensor

Connect the three leads (MID, END and GND) in the e-Health board.
Connect the EMG lead to the electrodes.
Adjustable Gain: You can adjust the EMG gain using the centered potenciometer in the top layer.
Remove the protective plastic
This sensor use disposable pre-gelled electrodes.
These high quality disposable electrodes are to be used to measure EEG, ECG and EMG. They are to be used once and are very handy because of integrated gel. They adhere very well to the skin and are clean to use.
The H124SG has a unique, patented pre-gelled adhesive side with non-irritating gel, especially developed to prevent allergic reactions. These foam electrode is latex free and therefore suitable for every skin type.
The snap-on connector can easily be pushed on or removed from the electrode lead.
Place the electrodes as shown below.

Library functions

Getting data
This EMG returns an analogic value in volts (read 0 – 1023 by the ADC) to represent the EMG wave form.
Example:
{
 float EMG = eHealth.getEMG();
}
            

Example

Arduino
Upload the next code for seeing data in the serial monitor:
Code:
Upload the code and watch the Serial monitor. Here is the USB output using the Arduino IDE serial port terminal:
Raspberry Pi
Code:
KST
KST program shows the EMG wave. KST

5. Visualizing the dataGo to index 

GLCD
The e-Health library includes functions to manage a graphic LCD for visualizing data. The Serial Graphic LCD backpack is soldered to the 128x64 pixel Graphic LCD and provides the user a simple serial interface.

Features

Connecting the GLCD
You need to connect the device with the signals in the correct position. The red wire that powers the module shows how to connect it.
The sensor measures are distributed in three screens that change by pressing the button.
In the first screen we can see some values like temperature, pulse or oxygen.
In the second screen is used for presenting the air flow wave.
When no respiration is detected, the screen will advise of a risk of apnea.
The last screen draws the ECG wave.
After the third screen, if you push the button again you will return to the first screen.

GLCD Library

The eHealth library includes all the necessary functions to manage the LCD and show in real time the data sensor measures. In order to use this functions, before all, you should include the corresponding library.
#include "eHealthDisplay.h"
            
Library functions:
Initializing the LCD
Use the init function in the setup before start using the LCD.
Example:
{
 eHealthDisplay.init();
}
            
Values Screen
In this screen you can see some numerical parameters like pulse, oxygen , temperature, amd a representation of the current body position.
Initializing
This screen must be initialized with the next function:
Example:
{
 eHealthDisplay.initValuesScreen();
}
            
Gettinga data
To refresh the values in the LCD execute the next function.
Example:
{
 eHealthDisplay.printValuesScreen();
}
            
AirFlow screen
In this screen we could see the air flow (breathing) wave and the number of breathings per minute. This screen includes an apnea adviser when no breathing is detected.
Initializing
This screen must be initialized with the next function:
Example:
{
 eHealthDisplay.initAirFlowScreen();
}
            
Gettinga data
To refresh the values in the LCD execute the next function.
Example:
{
 eHealthDisplay.printAirFlowScreen();
}
            
ECG Screen
This screen draws the electrocardiogram wave and measures the heart beat rate.
Initializing
This screen must be initialized with the next function:
Example:
{
 eHealthDisplay.initECGScreen();
}
            
Gettinga data
To refresh the values in the LCD execute the next function.
Example:
{
 eHealthDisplay.printECGScreen();
}
            
The push button
The eHealth board includes an integrated push button to change between the screen or it can be used like a general purpouse button for any application. The push button is routed to the digital pin 4.
Example:
Arduino
Upload the next code for seeing data in the GLCD:
Code:
The GLCD shows the information the nodes are sending which contains the sensor data gathered.

KST: Real-time data viewing and plotting

KST is the fastest real-time large-dataset viewing and plotting tool available (you may be interested in some benchmarks) and has built-in data analysis functionality. It is very user-friendly and contains many powerful built-in features and is expandable with plugins and extensions.
KST is licensed under the GPL, and is as such freely available for anyone. What's more, as of 2.0.x it is available on all of the following platforms: Microsoft Windows, Linux, Mac OSX.
Before all, you have to install the KST program in your PC. You can downloaded the program from KST web page:
We are going to use KST for representing the ECG wave, airFlow and galvanic skin response.

Example code

This example is for Linux OS. It will represent different waves and data measured by e-Health sensor platform.
You can find more information about how to use KST on this video tutorial.
To begin working with our real-time data must first load the appropriate code in the Arduino.
As we will work with Linux we will use the console to save data to a file (.txt).
Plug in the device, and execute
stty -F /dev/ttyACM0 cs8 9600 ignbrk -brkint -icrnl -imaxbel -opost -onlcr -isig -icanon
 -iexten -echo -echoe -echok -echoctl -echoke noflsh -ixon -crtscts
            
in console "A".
With this command we will configure the port ttyACM0.
Next, we use the command on the same console to create the text file where data will be stored.
tail -f /dev/ttyACM0 > Desktop/test.txt
            
The Arduino KST sample programs are ready to send data continuously when it receives a "C" and stop sending when it receive an "F". These data will be sent by console "B" with commands:
echo 'C' > /dev/ttyACM0
echo 'F' > /dev/ttyACM0
            

Basic configuration

Now with the file created and updated with data received, we have to open the program KST.
To configure KST for each example, we will need to set common parameters.
1) In pop-up window select the directory where the .txt previously created and press the Configure button.
2) The next step, is to configure the data source.
3) Select the measurement data. The data is field/column 2.
The final step is different depending on each example.

ECG example in KST

In this example we configure the KST to show a defined period of x time (x=300). We are interested only in the most current values of the ECG.
The Arduino code used in this program is presented next:
Code:

EMG example in KST

In this example we configure the KST to show a defined period of x time (x=300). We are interested only in the most current values of the EMG.
The Arduino code used in this program is presented next:
Code:

Galvanic Skin Response example in KST

In the Galvanic Skin Response example we are interested in all the data from the start of measurement. We will configure the KST to show a wave with all data.
Code:

AirFlow example in KST

We can configure the program according to the data we want to sample.

Serial Console

All data can be visualized in the serial monitor of Arduino/RasberryPi by using the next serial console program.
Load the example eHealth_SerialMenu program and open the serial monitor of Arduino IDE.
In the main menu we can find all e-Health sensors. By sending a command to the serial port we can select one of them.
To view the sensor measures, send the corresponding command and press enter key.
You can return to the main menu by sending the command “B”.
NOTE: The measurement of glucose has not been implemented in this example because both processes use UART communication and can cause malfunction
The Arduino code used in this program is presented next:
Code:

SmartPhone Application

The wifi module may perform direct communications with iPhone and Android devices without the need of an intermediate router by creating an Adhoc network between them.
We have developed the application e-Health Sensor Plattform, for both iPhone and Android platforms. The application may be also downloaded from the official App markets or from the Libelium website for free: http://www.cooking-hacks.com/apps
Official app markets URL’s:

Connecting to an iPhone

Installation
a) Download the application from App Store:
b) Download the application (e-Health.ipa) from the Libelium website: http://www.libelium.com/apps
  • Then double click on the icon, or right click and open with iTunes.
  • Inside iTunes, on the left panel, click on DEVICES->Your Device.
  • Select on the top “Apps”, and select Sync Apps. Drag into the desired screen e-Health app.
Once installed, the app appears in your iPhone/iPod screen.

iPhone app tutorial

The use of the app is very simple, first you have to connect to one of the Arduino nodes selecting it in Settings->Wi-Fi, and then launch the application.
To connect to the network created by the wifi module of Arduino: Go to Settings->Wi-Fi and select iPHONE_ADHOC.
Once connected, you can launch the App.
The App shows the information the nodes are sending which contains the sensor data gathered.
The first tab “Charts” shows:
The “Current data” tab, shows data that is in continuous change:
The “Tests” tab shows the information about:
Finally, in the “Movement” tab shows the position of the body.
NOTE: The measurement of glucose and blood pressure data has not been implemented in this example because both processes use UART communication and can cause malfunction
Example
Arduino
The Arduino code used in this program is presented next:
Code:
NOTE: This code only works with firmware 2.32 or 2.36 of wifi module Roving RN-171. In new firmware versions "set w j" command does not allow a "4" as an argument so adhoc mode is deprecated by the module manufacturer. It's possible to make a downgrade of the module firmware to the 2.32 or 2.36 version to be able to use this mode as in the code. However this process could break the module if it is not done correctly.

Connecting to Android

Installation
a) Download the application from Android Market:
b) Download the application () from Libelium website:http://www.libelium.com/apps
Once installed, the app appears in your device screen.

Android app tutorial

The use of the app is very simple, first you have to create an AP from your Android device and then set Waspmote to connect to it.
To create the AP from the Android device:
Go to Settings->Tethering & Portable Hotspot or Settings->Wifi-> My Wifi Zone (depending of the version of mobile).
Then configure the WLAN hotspot (name= ANDROID, Security= None).
Finally, enable Portable WLAN hotspot (or My Wifi Zone), and Arduino will connect to the Android device. Once connected, you can launch the e-Health App.
The App shows the information the nodes are sending which contains the sensor data gathered.
The first tab “Charts” shows:
The “Current data” tab, shows data that is in continuous change:
The “Tests” tab shows the information about:
Finally, in the “Movement” tab shows the position of the body.
NOTE: The measurement of glucose and blood pressure data has not been implemented in this example because both processes use UART communication and can cause malfunction
Example
Arduino
The Arduino code used in this program is presented next:
Code:

6. Sending the data to the Cloud.Go to index 

Telemedicine is the use of telecommunication and information technologies in order to provide clinical health care at a distance. It helps eliminate distance barriers and can improve access to medical services that would often not be consistently available in distant rural communities. It is also used to save lives in critical care and emergency situations.
Although there were distant precursors to telemedicine, it is essentially a product of 20th century telecommunication and information technologies. These technologies permit communications between patient and medical staff with both convenience and fidelity, as well as the transmission of medical, imaging and health informatics data from one site to another.
eHealth Sensor platform allows to share medical data with the cloud, and perform real-time diagnosis. Thanks to many communications modules can send data over several transmission protocols

Wifi

We will use the wifi module Roving RN-171. This module fits in the XBee socket of our Communication Shield and allows to connect your Arduino/RasberryPi shield to a WiFi network.
Example code
Wifi examples shows the way to communicate with the Arduino Wifi Demo Android and iPhone app.
Refer to Wifi tutorials (Arduino) (Raspberry) for more information.

Bluetooth

Bluetooth Modules for Arduino/Raspberry are able to be plugged into the XBee Shield and get a serial communication between the computer and an Arduino/RasberryPi board through Bluetooth protocol.
Bluetooth module PRO for Arduino supports Serial Port Profile (SPP) to exchange data with other devices. This profile allows to create connections to another device using the same profile (p2p connection). It sends data to the specified device. This device is the one which the connection has been created to.
Refer to Bluetooth tutorials (Arduino) (Raspberry) for more information.

Zigbee / 802.15.4

The Arduino Xbee shield allows your Arduino/RasberryPi board to communicate wirelessly using Zigbee.
Example code
This example shows the way to communicate with the Arduino using Zigbee protocol. Upload the next code:
Code:
NOTE: The Xbee modules must be configured previously. See the next link: Arduino XBee Shield Tutorial
Refer to XBee tutorials (Arduino) (Raspberry) for more information.

GPRS

GPRS Quadband Module for Arduino/Raspberry (SIM900) offers GPRS connection to your Arduino/RasberryPi board. You can send your data by SMS or do missed calls from your Arduino to mobile devices... or to another Arduino/RasberryPi connected to this module.
Example code
This example shows the way to communicate with the Arduino using Zigbee protocol. Upload the next code:
Code:
Refer to GPRS tutorials (Arduino) (Raspberry) for more information.

3G

The new 3G shield for Arduino/Raspberry enables the connectivity to high speed WCDMA and HSPA cellular networks in order to make possible the creation of the next level of worldwide interactivity projects inside the new "Internet of Things" era.
Example code
This example how to send data using 3G shield and making a connection to a server. Upload the next code:
Code:
NOTE: If you want to use the 3G module with the e-Health platform you must wire the ON 3G pin (digital 2) to an available digital pin in Arduino and power the e-Health board with a wire between Arduino and the shield (3V3).

Camera for Photo Diagnosis

This module allows to connect a camera for video recording and taking photos. Once saved the video or image file can be sent to an FTP or FTPS as you'll see later. Images with 3G Module tutorial.
Camera for the 3G shield
Insert the camera with metallic contacts facing up
Example Code
Take photos is very easy. Upload the next code.
Code:
Example picture 2: (Patient photo)
Snake bites occur when a snake bites the skin. They are medical emergencies if the snake is poisonous.
Sending images via 3g is a simple and rapid method for medical consultation
Refer to 3G tutorials (Arduino) (Raspberry) for more information.

Device CompatibilityGo to index 

This shield is tested and fully compatible with the following boards:

Arduino Boards

  • Arduino Uno

Raspberry Pi Boards

  • Raspberry Pi
  • Raspberry Pi (Model B+)
  • Raspberry Pi 2
  • Raspberry Pi 3

7. Forum.Go to index 

There is a forum available in which you can get support for e-Health platform.
SHARE

Oscar perez

Arquitecto especialista en gestion de proyectos si necesitas desarrollar algun proyecto en Bogota contactame en el 3006825874 o visita mi pagina en www.arquitectobogota.tk

  • Image
  • Image
  • Image
  • Image
  • Image
    Blogger Comment
    Facebook Comment

0 comentarios:

Publicar un comentario